Somewhere on the side of your local school, hospital, restaurant or office building sits a brass and bronze device that most people walk past without a second glance. It is a backflow prevention assembly, and its only job is to stop contaminated water from flowing backward into the public drinking water supply. These devices are tested every year by certified professionals, and the standard that defines what those professionals must know is now up for revision. ASSE International announced on November 3, 2026, that it is recruiting industry members for a working group to maintain and update ASSE/IAPMO/ANSI 5000, the Cross-Connection Control Professional Qualifications Standard, according to CONTRACTOR magazine. Applications are due December 15, and the working group will meet in person January 26 and 27 at ASSE International headquarters in Mokena, Illinois.

At Best Plumbers, we think backflow prevention is one of the most underappreciated jobs in plumbing. The people who test these assemblies quietly protect millions of people from contamination every day. This update is a chance to make sure they keep getting the training and credentials the job deserves, and we encourage qualified plumbers, testers and inspectors to get involved.

What Is ASSE/IAPMO/ANSI 5000?

ASSE/IAPMO/ANSI 5000 sets the minimum professional qualifications for people involved in backflow prevention, primarily those who test backflow prevention assemblies. It also establishes the requirements for the ASSE/IAPMO/ANSI 5000 Professional Qualifications certification programs that many jurisdictions recognize.

According to CONTRACTOR, the standard covers people working with assemblies that meet the performance requirements of seven ASSE product standards:

  • ASSE 1013: reduced pressure principle assemblies, often called RPZs or RP assemblies.
  • ASSE 1015: double check backflow prevention assemblies.
  • ASSE 1020: pressure vacuum breaker assemblies.
  • ASSE 1047: reduced pressure detector fire protection assemblies.
  • ASSE 1048: double check detector fire protection assemblies.
  • ASSE 1052: hose connection backflow preventers.
  • ASSE 1056: spill resistant vacuum breakers.

Terry Burger, ASSE/IAPMO's senior director of standards development, said the standard addresses the need for professional qualifications standards in the plumbing and mechanical industries. ASSE's Professional Qualifications Standards Committee maintains it under accredited standards development procedures.

The Working Group: Who Can Apply

ASSE is inviting a broad range of stakeholders to help revise the standard, including installers, manufacturers, plumbing professionals, building owners and managers, engineers, authorities having jurisdiction and members of the general public. The key details reported by CONTRACTOR:

  • Application deadline: December 15.
  • Meeting: In person, January 26 and 27, at ASSE International headquarters in Mokena, Illinois.
  • How to apply: Online through ASSE's working group application page, or by emailing a completed application and résumé to ASSE's standards department.

If you are a certified backflow tester, a cross-connection control program manager or a plumbing inspector, this is a rare opportunity to shape the qualifications for your own profession. Standards are written by the people who show up.

Backflow Explained in Plain English

Water in a public system is supposed to flow one way: from the treatment plant, through the mains, into buildings and out of the tap. Backflow is when water flows the wrong way, from a building back into the supply. It happens in two main ways.

Backsiphonage

Backsiphonage occurs when pressure in the supply drops, often because of a water main break, heavy firefighting demand or a large flushing operation. The drop can create a vacuum that pulls water backward out of buildings, just like sucking on a straw. If a garden hose is lying in a bucket of fertilizer or a pool, that liquid can be pulled into the plumbing.

Backpressure

Backpressure occurs when pressure inside a building's system rises above the supply pressure. Boilers, pumps, pressurized tanks and elevated storage can all push water backward into the public supply if there is no protection.

Cross-connections

A cross-connection is any point where drinking water could come into contact with something that is not drinkable: chemicals, irrigation water, boiler water, fire sprinkler water, medical equipment, soda machines, sewage and more. Backflow prevention devices are installed at these points so that even if pressure conditions change, contaminants cannot get into the drinking water. We explain the basics in our guide to backflow prevention explained.

Why This Is Serious

Backflow incidents are not theoretical. Over the decades, public health records have documented cases where antifreeze, pesticides, industrial chemicals, carbonated beverage systems, boiler treatment chemicals and even sewage entered drinking water through unprotected cross-connections. Some caused illness; some forced boil water notices or do not drink orders for entire neighborhoods. In many cases, a properly installed and tested backflow preventer would have stopped the problem.

That is why many water utilities run cross-connection control programs that require annual testing of backflow assemblies on commercial, industrial, irrigation and fire sprinkler connections. The tester's report is the proof that the device is working.

What a Backflow Test Involves

A certified tester uses a calibrated differential pressure gauge kit connected to the assembly's test cocks. The exact procedure depends on the device type, but for a reduced pressure principle assembly a tester typically:

  1. Notifies the building owner because water service may be briefly interrupted.
  2. Closes the downstream shutoff valve.
  3. Connects the test kit hoses to the appropriate test cocks and bleeds air from the system.
  4. Checks that the first check valve holds a minimum pressure differential.
  5. Verifies that the relief valve opens at the correct differential.
  6. Tests the second check valve for tightness against backpressure.
  7. Records the readings, restores service and submits the report to the owner and, usually, the water utility.

If a device fails, it must be repaired or replaced and retested. Precision matters. A tester who reads a gauge wrong or skips a step can pass a failing device, leaving a building and its neighbors unprotected. That is exactly why qualification standards like ASSE 5000 exist.

What Makes a Qualified Tester

Qualification standards typically address a tester's knowledge of hydraulics and backflow theory, familiarity with device types and their correct installation, test procedures for each assembly, gauge calibration and care, recordkeeping and reporting, safety, and the codes and local rules that govern cross-connection control. Certification usually requires both a written exam and a hands-on practical exam on real devices, and periodic recertification keeps skills current.

As devices evolve and new types of cross-connections appear, from commercial coffee systems to building-integrated water treatment, the qualifications need to keep pace. A revision is a chance to address new technology, clarify procedures and strengthen consistency across jurisdictions.

Where You Will Find Backflow Preventers

Backflow protection shows up in more places than most people realize. Common locations include:

  • Lawn irrigation systems, where fertilizers, pesticides and animal waste can be drawn back through sprinkler heads. A pressure vacuum breaker or RPZ is usually required.
  • Fire sprinkler systems, where water can sit stagnant for years and may contain treatment chemicals. Detector assemblies under ASSE 1047 and 1048 are common.
  • Boilers and hydronic heating systems, which often contain chemical treatment and operate under pressure. Our recent article on the 2028 circulator pump standard touches on these systems.
  • Restaurants and commercial kitchens, including soda fountains, coffee and espresso machines, dishwashers and chemical dispensers.
  • Hospitals, labs and dental offices, where medical and laboratory equipment can introduce dangerous contaminants.
  • Car washes, factories and processing plants, which handle detergents, oils and industrial chemicals.
  • Outdoor hose bibbs at homes, where a simple hose connection vacuum breaker under ASSE 1052 protects against a hose left in a pool or bucket.

What Homeowners Should Know

Most backflow testing happens at commercial properties, but homeowners have responsibilities too. If your home has an irrigation system, fire sprinklers, a pool fill line, a boiler or a well connected to a municipal system, your water utility may require a backflow preventer and annual testing. You may receive a letter or notice each year reminding you that a test is due.

Please do not ignore those notices. Utilities can shut off water service to properties that fail to submit test reports, and an untested device may be quietly failing. Hire a certified tester, ideally a licensed plumber with backflow certification, so that any needed repairs can be made on the spot.

Simple steps every homeowner can take:

  1. Install hose bibb vacuum breakers on outdoor faucets if your home does not already have frost-free hydrants with built-in protection.
  2. Never leave a hose submerged in a pool, pond, bucket, sink or chemical container.
  3. Do not use hose-end sprayers with fertilizer or pesticide unless the faucet is protected.
  4. Know where your irrigation backflow device is and protect it from freezing in cold climates. Our winter plumbing tips and guidance on combating frozen pipes apply here too.
  5. Keep test reports with your home records.

Our earlier article, the little valve that guards your tap, explains why backflow prevention has been drawing more attention this year.

Pressure Events Make Testing Matter More

This year has brought a wave of water main breaks and pressure drops across many cities, especially as freezing weather hits aging infrastructure. Every main break is a potential backsiphonage event. When pressure collapses in a neighborhood, any unprotected cross-connection becomes a pathway for contamination. Our guide on what to do during a boil water advisory covers how to respond after such events, and our feature on the age of drinking water pipes explains why breaks are so common.

Properly working backflow preventers are the safety net that keeps those pressure events from becoming contamination events. That is why the quality of testing matters so much.

How Codes and Standards Fit Together

Backflow protection sits at the intersection of several systems. Model plumbing codes, such as the Uniform Plumbing Code and the International Plumbing Code, tell designers and installers where backflow protection is required and which type of device fits each hazard. Product standards such as ASSE 1013 and 1015 define how devices must perform. Qualification standards like ASSE 5000 define who is competent to test, inspect and manage them. And water utilities enforce cross-connection control programs locally.

When any one of those pieces is weak, the whole system is weaker. We covered the latest code edition in the 2027 Uniform Plumbing Code is here, and the PHCC's new leadership recently emphasized partnerships with code bodies like IAPMO in our article on PHCC's new CEO.

Backflow Warning Signs and Scams to Avoid

Like any specialized service, backflow testing attracts a few bad actors. Watch out for:

  • Testers who cannot show current certification recognized by your water utility. Ask for the certification number and check it if your utility publishes a list.
  • Uncalibrated gauges. Test kits must be calibrated regularly. A reputable tester can show the calibration date.
  • "Paper tests", where a report is filed without the device actually being tested. If the tester never shut down your water or connected hoses, be suspicious.
  • Pressure to replace a device that only needs a repair kit. Many failures are fixed with new rubber parts, springs or seats.

Physical signs that a device may need attention include water constantly discharging from an RPZ relief port, visible leaks, corrosion, freeze damage, or a sudden drop in water pressure downstream. A relief valve that spits water occasionally during pressure swings can be normal, but continuous discharge is a sign of a fouled check valve and should be checked promptly. Find more guidance in our helpful plumbing advice library.

A Great Specialty for Plumbers

For plumbers looking to grow, backflow certification is one of the most valuable add-ons available. It brings recurring annual testing work, steady commercial relationships and a respected role in protecting public health. Many plumbing companies build entire service divisions around backflow testing, repair and cross-connection surveys. If you are an apprentice or journeyman, it is worth asking your employer about training. Browse opportunities on our plumbing jobs board.

Our Take

We applaud ASSE for opening this standard to a broad working group. The best standards are written with input from people who actually do the work, along with manufacturers, engineers, regulators and the public. If you have the expertise, apply before December 15 and help shape the future of cross-connection control.

And for building owners and homeowners: treat backflow testing as essential, not optional. When you need a certified tester or a licensed plumber to repair a failing device, Best Plumbers can help you find trusted plumbers near you, with honest reviews to help you choose. Business owners can also review our guide on how to find a good plumber before hiring.

Frequently Asked Questions About Backflow Testing and the ASSE 5000 Standard

1. What is ASSE/IAPMO/ANSI 5000?

The Cross-Connection Control Professional Qualifications Standard, which sets minimum qualifications for people who test backflow prevention assemblies.

2. What did ASSE announce?

ASSE International is recruiting working group members to help maintain and revise the ASSE 5000 standard.

3. When is the application deadline?

December 15, according to CONTRACTOR magazine.

4. When and where will the working group meet?

January 26 and 27 at ASSE International headquarters in Mokena, Illinois.

5. Who can apply to the working group?

Installers, manufacturers, plumbing professionals, building owners and managers, engineers, authorities having jurisdiction and the general public.

6. Which device standards does ASSE 5000 cover?

Assemblies meeting ASSE 1013, 1015, 1020, 1047, 1048, 1052 and 1056.

7. What is backflow?

The unwanted reverse flow of water from a building back into the public drinking water supply.

8. What is backsiphonage?

Backflow caused by a drop in supply pressure that pulls water backward, like a straw.

9. What is backpressure?

Backflow caused when pressure inside a building's system exceeds the supply pressure.

10. What is a cross-connection?

Any point where drinking water could contact a non-drinkable substance.

11. What is an RPZ?

A reduced pressure principle assembly, a high-hazard backflow preventer with two check valves and a relief valve.

12. What is a double check assembly?

A backflow preventer with two independently acting check valves, used for lower-hazard applications.

13. What is a pressure vacuum breaker?

A device that protects against backsiphonage, commonly used on irrigation systems.

14. How often are backflow assemblies tested?

Many water utilities require annual testing, plus testing after installation or repair.

15. Who can test a backflow assembly?

A certified backflow tester recognized by the local water utility or authority.

16. What happens if a backflow device fails a test?

It must be repaired or replaced and retested before being returned to service.

17. Do homes need backflow preventers?

Many homes with irrigation systems, fire sprinklers, pools or boilers need them. Check local requirements.

18. Why is backflow testing important?

It verifies that devices protecting public drinking water actually work.

19. What tools do backflow testers use?

A calibrated differential pressure gauge test kit with hoses and fittings.

20. Can I test my own backflow preventer?

Generally no. Most utilities require tests by certified testers and reports filed with them.

21. Who is Terry Burger?

ASSE/IAPMO's senior director of standards development.

22. What is ASSE International?

An organization that develops plumbing and mechanical product and professional qualification standards.

23. How do I become a certified backflow tester?

Complete an approved training course and pass written and practical exams, then recertify periodically.

24. Is backflow a problem outside the US?

Yes. Many countries require backflow protection under their plumbing and water regulations.

25. How do I find a plumber who does backflow testing?

Use Best Plumbers to find licensed plumbers near you and ask about backflow certification.

Sources


Latest from the Plumbing Blog View All
See all Best Plumbers articles →

Satisfaction Promise

We'll always connect you with the best plumbers that meet your specific needs.

Are you a plumber?

1. Register a member account
2. Create a searchable listing
3. Connect with more clients

Get Listed Today